The water path / a gutter and drainage manual for St. Louis Keys Roofing / (314) 220-2333
Seamless Gutters STLGutters · guards · drainage Call (314) 220-2333

The water path / The gutter year

Seasonal / the calendar

A Downspout Discharge Beside Your AC Condenser Wets the Coil

Water from a downspout that lands near your air conditioner condenser can splash the fins and undermine the pad. Here is how to check it.

Many St. Louis homeowners put the outdoor condenser on whatever side of the house had room for it, and the downspout goes wherever the gutter drains. Those two decisions were often made by different people, years apart, and nobody checked whether the roof water would land on the unit. If a downspout empties within a few feet of the condenser, the water hits the pad, splashes up into the fins, and sits there after the rain stops.

What the splash does to the coil

The condenser coil is a bank of thin aluminum fins with tubing running through them. Its job is to shed heat into the air that moves across it. When a downspout dumps a steady stream onto the pad beside the unit, the spray reaches the lower fins and coats them with whatever the roof and gutter carried: grit from the shingles, pollen, leaf fragments, and the mineral residue left when water dries. Over a season that film traps dust and turns into a mat that slows the airflow.

A wet fin collects that mat faster. Clay soil across much of St. Louis County holds water for days after a storm, so the bottom of the unit can stay damp long after the sky has cleared. Damp dirt and debris at the base of the coil is where the fins begin to look dull or stained. The stain is cosmetic at first. The restriction it causes is not, because the unit has to work harder to move the same amount of heat, and that extra work shows up most on the hottest afternoons of July and August, when the unit runs longest.

What the water does to the pad

A concrete pad is set level so the unit sits flat on it. Water that runs off a downspout and pools against one edge can wash out the soil underneath that edge over time. In winter, any water left in that low corner freezes and thaws, and each cycle lifts the slab a little more. Once one corner settles, the unit can tilt. A tilted unit can strain its mounts and the refrigerant piping that connects to it. Pad settling is slow, so most homeowners only notice it after the unit has been leaning for a season or two.

The pad problem and the coil problem tend to arrive together. The same splash that dirties the fins is also soaking the soil that holds the pad. Fixing one without the other leaves the second problem in place, so the check should cover both.

Check it after a hard rain

You do not need a tool to see the problem. Wait for a rain of about an inch, then walk to the unit while the downspout is still running or just after it stops. Look at where the water lands. If it hits the pad, the splash line shows how far it reaches and whether it touches the lower fins. Look at the bottom three or four inches of the coil for a wet, dirty band. Then look at the soil under the pad edge for a washed-out gap or a dark, soft patch. Note the condensate drain on the side of the unit as well, since a second line of water running near the pad is easy to miss later.

Take photos with the date stamp on, from two angles: one showing the downspout outlet and the pad, and one close to the coil. If you call anyone about the problem, the photos will show the spot faster than a description will.

What the fix usually involves

The simplest fix is at the outlet. A downspout extension that carries the water several feet away from the unit, and sends it onto a splash block or into a drain, moves the discharge out of the condenser's reach. The extension should be pitched away from the house so it does not pool at its own end, and it should not cross the path to the unit or the service side of the cabinet. Do not turn the outlet toward a neighbor's side yard or onto a walk, because that trades one wet spot for another.

If the lot is too tight for an extension, the outlet can be run to a buried line or a dry well. That is a separate job with its own digging, so it should be quoted on its own line rather than folded into a general gutter price. Moving the condenser itself is a different job again. It involves the refrigerant lines and the electrical disconnect, so that work belongs to the heating and cooling company, not the gutter crew.

What to ask your gutter contractor

  • Where does this downspout discharge, measured from the edge of the condenser pad?
  • Will the extension or redirect move the outlet clear of the unit, and to what point on the lot?
  • Does the quote include the splash block, buried line or dry well, or only the extension?
  • Who checks the unit's clearance and the pad if the outlet change requires any work near it?
  • Is the extension secured to the wall so a mower or a child cannot knock it loose?

What to ask your heating and cooling company

Ask the HVAC company to inspect the coil and the pad after the downspout change. They can clean the fins with the right method and reset the unit level if it has shifted. Ask whether the pad needs re-leveling before or after the water is redirected, because a pad that has already settled may need work first, and doing the gutter side first without checking the pad can leave the unit tilted. Have the condensate line checked at the same visit, since a clogged line can add water to the same spot and blur the cause.

Ask them to note the condition of the fins in writing. If the fins are already bent or the coil is clogged deeply, the cleaning will not reverse the wear, and you should know that before the summer heat starts.

Where to start

Start with the photo file and the walk. The gutter side of the problem belongs to the gutter contractor, and the coil and pad belong to the HVAC company. When the answers come from two different people, write them down with dates so the splash is not passed back and forth between them. Hail on the fins is a separate question with its own photo set, so keep that file apart from the splash file. For a quote on the downspout work or a second look at the outlet, call Seamless Gutters STL at (314) 220-2333.

Ask about the two weeks

Book it before the leaves have finished falling

The check that matters most is the one almost nobody does: a hose down every downspout once the trees are bare, with somebody at the bottom watching where the water actually comes out.

If you would rather not be the person on the ladder for that, say so, and tell us how many storeys we are talking about.

(314) 220-2333

Straight through to the Keys office. Roofing, gutters and downspouts only, across greater St. Louis.

A name and a number is enough. Someone from Keys will call you back.