The water path / a gutter and drainage manual for St. Louis Keys Roofing / (314) 220-2333
Seamless Gutters STLGutters · guards · drainage Call (314) 220-2333

The water path / The gutter year

Seasonal / the calendar

Gutters Under a Solar Array Need the Drip Line Measured First

A solar array edge sets where the trough can sit, where the hangers can land, and where the water drops, so measure it before you compare guard prices.

A solar array on a St. Louis roof changes the gutter line in ways the first quote often leaves out. The panels sit a few inches above the shingles, and their lower edge can project past the eave. That edge decides where rain runs off, where the trough can sit without being struck by the panel frame, and whether a guard can be fitted without cutting through a wire tray or a racking rail. Before you compare gutter prices, measure the drip line under the array and write the figures down.

Why the panel edge matters more than the shingle edge

On a plain roof, the drip line sits at the eave, and the gutter front is set a fixed distance out from the fascia. Under a solar array, rain that falls on the glass runs off the lower edge of each module and lands in a line that may be several inches farther out than the shingle edge. If the trough sits where the shingle edge used to be, the panel edge can drop water over the front lip, or it can sheet onto the back of the trough and run toward the fascia. Either way, the trough is working against a load the original installer may never have planned for.

Snow adds a second problem. Snow tends to slide off the glass in sheets rather than in the slow creep you see on bare shingles. A sheet can land on the trough front in one piece, and the melt that follows can refreeze at the lip during a St. Louis cold snap. None of this means the gutter should be skipped. It means the trough, the hangers and the outlet need to be set for the drip line the array actually creates.

Measure three distances before the trough is cut

  • The distance from the fascia to the lowest edge of the lowest module row, taken at each end of every run and at the midpoint.
  • The vertical distance from that module edge down to the top of the existing or planned trough.
  • The clearance between the bottom of the racking rails and the top of the gutter hangers, so a hanger does not land on a rail bracket.

Write each figure on the same sketch as the outlet positions. A single number for the whole house is not enough, because an array rarely runs the full length of the eave. A run under the array and a run beside it may need different hanger spacing, and the quote should say which is which. If the crew only measures the shingle edge and writes one figure for every eave, ask them to measure again under the modules before the order is placed.

Where the hangers can and cannot land

Racking hardware and conduit runs often sit in the same band along the eave as the hanger screws. A hanger that lands on a conduit clamp will not seat properly, and drilling near a live wire run is not a repair a gutter crew should make on its own. If the array owner has a drawing of the rail and conduit positions, ask for a copy before the crew arrives. If there is no drawing, the crew should mark the rail brackets with chalk along each eave and photograph the marks before any hole is drilled.

Keys Roofing documents the rail positions as part of the written scope, with photos and measurements, so the homeowner has the same record the crew used. Whoever owns the array still needs to confirm which parts are live and which are only mounted. A gutter crew can tell you where the fascia is solid. It cannot tell you whether a conduit is energized.

Guard fit under the module edge

A gutter guard adds height at the front, and it can catch the lowest module edge if the guard lip sits too high. Check the guard standoff against the module drip line, not against the shingle edge. Ask the guard maker for the bracket height and the lip profile, then ask the crew to show, on a sample section, where the guard lip stops relative to the module row.

Leave a gap at the panel edge rather than fitting the guard tight. Guard materials expand and contract with the summer heat, and a lip that sits against a hot module frame in July can buckle or pull a clip by the following spring. The gap is small, but it is the difference between a guard that moves with the season and one that binds.

When the array stops short of the eave

Many arrays do not run the full length of the roof edge. The panels may stop at a dormer, a chimney or a valley, and the eave beyond them has bare shingles. This creates two drip lines on one trough, and the outlet has to serve both. The shingle section will drip at its own line, and the panel section will drip at a farther line. If the trough is pitched for the shingle edge alone, the panel section can overflow at its ends.

Measure where the array begins and ends along the eave, and mark those points on the sketch. Ask the crew whether the trough pitch changes at the array ends, and whether the outlet sits on the shingle side or the panel side. A downspout on the panel side will catch more water in a heavy storm, so its size and the number of outlets should reflect that.

Winter melt and where it lands

Melt from under and beside the array can refreeze at the trough front on a cold morning, and that ice sits closer to the house than ice from a bare eave. The front hem and the outlet placement decide whether melt reaches the downspout or stalls on the walk below. Measure the outlet to the lowest module corner so the drop does not land on a bed, a walk or a patio that the array shades through the winter.

If the outlet ends above a concrete walk, ask who will clear the ice and whether the crew has an opinion on a splash block or an extension. A splash block on St. Louis clay still needs a route for the water after it leaves the block. Put that route on the sketch so the outlet is not left to find its own way.

What to ask the gutter crew before you sign

  1. Where the drip line sits under each module row, in inches from the fascia, at each end and at midspan.
  2. Which hanger screws land near a rail bracket or a conduit clamp, and whether the crew will move them to a solid spot.
  3. Whether the guard lip stops short of the module edge, and by how much, shown on a sample section.
  4. Who handles any work near the conduit or the racking, and whether that work is in the gutter price or stays with the array owner.
  5. Whether the written scope includes dated photos of the eave under the array before the trough goes up.
  6. Where the outlets sit relative to the array ends, and what the splash route looks like at grade.

Keep the sketch, the photos and the measurements in one folder with the quote. If the array owner later asks why a hanger sits where it does, the record answers the question without anyone reconstructing it from memory. Questions about the array's warranty, its wiring or its own mounting hardware belong with the array installer, not with the gutter crew. For a site visit or a written scope under a solar array, call Keys Roofing at (314) 220-2333.

Ask about the two weeks

Book it before the leaves have finished falling

The check that matters most is the one almost nobody does: a hose down every downspout once the trees are bare, with somebody at the bottom watching where the water actually comes out.

If you would rather not be the person on the ladder for that, say so, and tell us how many storeys we are talking about.

(314) 220-2333

Straight through to the Keys office. Roofing, gutters and downspouts only, across greater St. Louis.

A name and a number is enough. Someone from Keys will call you back.